GAS
AND FUME DETECTION, ALARM, CONTROL AND DISPLAY MODULES |
 |
 |
GS
2
TWO
CIRCUIT GAS DETECTION, ALARM & LPG CONTROL KIT.
The
self contained flush mount GS 2 Controller Module, features LED
backlit status display, 2x LED bargraphs of % LEL, sensor fault
monitoring & warning, sealed touch switch controls for greater
reliability, and plug-in terminals on the rear for simple installation
of site wiring. Kit includes GS2 Module, 2x gas sensor assemblies,
Ix gas solenoid valve. Operation of gas On/Off switch turns gas
supply on and off, with audible and visual alarms and automatic
gas shutoff if a gas leak is detected.
Download pdf
|
 |
 |
FD
2
TWO
CIRCUIT FUME DETECTION, ALARM & FAN CONTROL KIT.
The
self contained flush mount FD 2 Controller Module, features LED
backlit status display, 2x LED bargraphs of % LEL, sensor fault
monitoring & warning, sealed touch switch fan controls, alarm
isolate/resets, test and dimmer. Plug-in terminals on the rear
simplify termination of site wiring. Kit includes FD 2 controller
module & 2x gas sensor assemblies. Operation of either fan
control On/Off switch turns that blower fan on and off, with audible
and visual alarms and automatic Fan Start if fumes are detected.
Download pdf
|
 |
 |
TS12
TWELVE
(12) SEALED TOUCH SWITCH CONTROL MODULE
Twelve
sealed touch switch controls with LED On indication in each switch
for control both local & remote equipment. Suitable for momentary
or On/Off control. Switches custom labelled to suit your applications.
Power supply 12 or 24 volts DC. Wiring terminates on plug-in terminals
on the rear of the sealed flush mount TS12 Module, with local
relay driver outputs to drive remote switching relays, which are
supplied in banks of 6 PCB mounted relays for installation in
your switchboard. |
TT2
TRIM TAB CONTROL
Single or Dual station Trim Tab controller 20 LED feedbac position display & interlocked relay hydraulic control drives.
Download pdf
|
|
 |
 |
NAVCON-8
NAVIGATION
LIGHT FAULT MONITOR & CONTROL KIT
Compact
flush mount module provides touch switch On/Off control of eight
navigation lights, each with fault monitoring of the Nav Light
Circuit, with red LED visual & common audible, fault warnings,
in case of bulb or circuit failure. A green Nav Light On LED is
provided for each healthy Nav Light Circuit On. The Fault Monitoring
is arranged in four groups (Steaming, Anchor & NUC. &
No Lights On When Dark) with individual group fault acknowledge
switches. 12 or 24 volts DC. Plug-in terminals on rear. for wiring
to remote control relays & stud mount sensing diode assemblies
to be mounted in nav light switchboard.
Download pdf
|
 |
 |
CUSTOM
ALARM MONITORING & DISPLAY SYSTEMS
We
also manufacture & supply custom systems to your requirements.
These can include plans and profile views of your vessel with
LED backlit status display & touch switch in position on the
plan views. All finished in colours to match your wheelhouse decor.
Custom systems can include any combination of alarms and run indications,
typically including Fire, Bilge & Tank Alarms, Pumps Running,
W.T.D. and Porthole Monitoring, Navigation Light Control and Fault
Monitoring, Exhaust Temperature Display & Alarms, Engine,
Generator and Hydraulic System Alarms etc. |